Specifications
Model Number CPLMB 14000E
Cooling Capacity 14,000 BTU/hr
Power Consumption 1,100 W / 9.8 A
Humidity Removal Capacity 80 pints / Day
Recommended room size Up to 400 sq. ft.
Power Supply 115V / 60Hz / 1 Phase
Compressor Rotary
Refrigerant R-22
Fan Speed 3 (2 + 1 Turbo)
Temperature Set Range 64°F - 90°F
Timer 0-24 hours
Weight 75 lbs.
Dimensions 20"W x 16"D x 33"H
REMARKS:
The cooling capacity of the unit may be affected
by the height of the ceiling, quality of insulation,
number of windows, etc.
2
Emptying the Internal Water Container
NOTE: A proper balance between temperature and humidity is critical to maintain a comfortable
living environment. If humidity is high, it will be necessary to empty the Internal water container
frequently, until the ideal humidity is reached.
When the internal water container is full, the back light on the LCD
display flashes. The unit will shut off automatically, beep 15 times and must
be drained before it will restart.
To Drain the Unit:
• Switch off the unit and remove the plug from the wall socket.
• DO NOT MOVE THE UNIT. Doing this can result in water
leakage, damaging your floor or carpet.
• Place the drain pan on the floor under the drain cap.
• Remove the drain cap and the rubber stopper from the
drain, and let the water run out. Partially fill the drain pan,
replace the rubber stopper, and empty the drain pan.
This procedure must be repeated until the unit is empty.
• Replace the rubber stopper and drain cap.
Put plug into the wall socket, and switch the unit on.
The warning signal should be off.
For Continuous Drainage:
• Switch off the unit and remove the plug from the electrical outlet.
• Remove the Drain Cap and Rubber Stopper. Drain if necessary.
• Connect a Drain Tube (not included) (20mm / 3/4" inner dimension) on to the water outlet.
• Place the other end in a drain. Make sure the tube is free from twists and bends.
The tube must decline over its entire length.
NOTE: When restarting the unit it may take up to 3 minutes for the compressor to turn on.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Amcor CPLMB 14000E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Amcor CPLMB 14000E in the language / languages: English as an attachment in your email.

The manual is 8,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info