MPT-250B SPECIFICATIONS AND
OPERATING INSTRUCTIONS
DATASHEET
______________________________________________________________________
Daniels Manufacturing Corporation, 526 Thorpe Road, Orlando, FL 32824, U.S.A.
Phone: (407) 855-6161 Fax (407) 855-6884 www.dmctools.com Email: dmc@dmctools.com
Copyright©2013 All Rights Reserved Page 3 of 6 Rev. M 10/13 MPT-250B-DS
3.2.2 Ring Terminal Lower Grip (Optional)
If the ring terminal lower grip has been ordered, installation is as follows:
A. Remove the screw holding the standard lower grip in place.
B. Substitute the optional grip for the standard grip and tighten the screw until the lower grip rotates with
resistance but is not loose or does not need to be forced to turn.
3.3 FRONT PANEL CONTROLS
3.3.1 MOTOR CONTROLS
NOTE: PRESS AND HOLD SWITCHES FOR APPROXIMATELY 1 SECOND TO ALLOW FOR PROPER ACTIVATION.
START Motor start switch to begin test.
RESET Resets display meter to zero, and resets pull wheel to START position for the next test. RESET must be
performed after each test.
STOP Stops the motor and the meter retains the current peak value.
3.3.2 RATE OF PULL CONTROLS
LO-HI SWITCH
LO (Green) selects rate of pull of 1-5 in/min.
HI (Yellow) selects rate of pull of 6-10 in/min.
NUMBERED RATE SWITCHES
Select the rate of pull, 1-5 in/min (LO-Green), or 6-10 in/min (HI-Yellow) as chosen by setting of LO-HI switch.
3.3.3 DISPLAY CONTROLS
ZERO Adjusts the display to true zero. When turned counterclockwise the meter reading will decrease. When
turned clockwise the meter reading will increase. The display will be checked for zero adjustments at startup and
after each test when the RESET switch is pressed.
RESET Resets the display (clears peak values) to zero.
3.4 OPTIONAL CONTROLS ON THE FRONT PANEL
3.4.1 SETPOINT The SETPOINT option enables an operator to set the force at which the MPT-250B is to stop
automatically if the test proceeds to that force and the connection under test does not fail.
When the SETPOINT/MEASURE switch is held in the MEASURE position it enables the operator to select the set
point by turning the SET adjusting knob next to the switch. As the knob is turned, the set point force will be
indicated on the display meter. Clockwise adjustment increases the set point value, and turning the knob
counterclockwise decreases the value. The force reading from the load cell is disabled, and will not be enabled
until the switch is in the SETPOINT (raised) position. Tests are conducted with the switch in the raised position.
When the load reaches the set point level, the motor will stop and the unit can be reset and reloaded for the next
test.
NOTE: The unit must be turned off, and then back on for the set point measure changes to take
effect.
This option can be used in conjunction with the AUTO STOP (section 3.5.1) feature. When both features are
turned on, the test will stop automatically if either condition is met (AUTO STOP, or SETPOINT).
If the peak reading of the force necessary to part a connection is desired, the set point should be at 249.9lb
before testing.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alphatron MPT-250B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alphatron MPT-250B in the language / languages: English as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info