684785
50
Zoom out
Zoom in
Previous page
1/52
Next page
50
Technische Änderungen vorbehalten | 83059000dDE – Originalbetriebsanleitung | ait-deutschland GmbH
Stromlaufplan 2/2 Wärmepumpenmodul
LWCV 122R3
LWV122R
-
-K50
Legende:
Betriebsmittel
B10
B11
K21
K22
K23
K50
R1
R3
R4
R5
R6
X200
-X20
HD
ND
EEVH
EEVC
TSG1
TFL1
TFL2
THG
TWE
-X12
DE
Funktion
Hochdrucksensor
Niederdrucksensor
Abtauventil
Elektronisches Expansionsventil Heizen
Elektronisches Expansionsventil Kühlen
Reglerplatine Kältekreis
Sauggasfühler Verdichter
Flüssigkeitstemperatur Heizen
Flüssigkeitstemperatur Kühlen
Heissgasfühler
Wärmequelle Eintrittsfühler
Stecker Steuerung
817441
-X11
-X200
-X1 -X3
-K21
-X17
-K22
-X18
-K23
-X8
-R1
-R3 -R4
-R5
-XE
-R6
-B10
-X15
-B11
123 45678
12 8
A
B
C
D
E
F
A
B
C
D
E
F
Blatt
Bl.
2
2
3 4567
AIT
817441
Stromlaufplan
ait-deutschland GmbH
PEP
22.09.2016
AP
Mod-A+ Ven
/1.B8
Mod-B- Ven
/1.B8
Mod-A+
/1.C2
Mod-B-
/1.B2
Mod-GND
/1.C2
weiß
222
grün
333
braun
444
1
PE-Steu
/1.B8
A/B/.../+12V/GND
L
L-Steu
/1.B8
N
N-Steu
/1.B8
K1
N
EEVH EEVC
blau
1
TSG1
blau
2
schwarz
4
EEVH
TFL1
schwarz
5
schwarz
7
EEVC
TFL2
schwarz
8
rot
10
THG
rot
11
blau
13
1
TWE
blau
14
2
31
32
HD
I
P
1
2
3
ND
I
P
4
5
6
Änderung Datum
Datum
Bearbeiter
Geprüft
NormName
24.09.2014
Pfleger
R.
1
2
7
3
6
1
weiß
12345
2
grün
5
6
gelb
braun
1
Orange
Red
Yellow
Black
Grey
2
3
4
5
1
Orange
Red
Yellow
Black
Grey
2
3
4
5
White
Green
Brown
White
Green
Brown
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alpha innotec LWCV serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alpha innotec LWCV serie in the language / languages: German as an attachment in your email.

The manual is 5,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info