684773
38
Zoom out
Zoom in
Previous page
1/40
Next page
38
Technische wijzigingen voorbehouden | 83051400cNL vertaling van de installatie- en gebruikershandleiding | ait-deutschland GmbH
L Reg
/1.13
MOT
/1.13
R23
/1.13
N Reg
/1.13
PE
/1.13
12
-X12
L
-X7
6
1
11
N
P
+-
b2 c4
a1
-F1
HDP
5
12
/1.6
34
/1.6
56
/1.6
21 22
/1.6
1
A1
A2
-K1
VD1
10
-X12
A1
A2
-K3
7
-X12
2
-X7
-Y1
3
-X12
P
+-
c4
a1
-F2
NDP
P
-+
c4
a1
-E1
AEP
9
-X12
ϑ
1
-X52
-R4
TRL
2
ϑ
3
-R5
TVL
4
ϑ
5
-R6
THG
6 7 8 9
29
-X7
-R10
CW
10
30
ϑ
11
-R7
TWEFS
12
12
/1.9
34
/1.9
56
/1.10
21 22
/1.11
R7 TWEFS Voeler bevriezingsbeveiliging
THG
1
ND
VBO
AV
-E1
PE
-F1
N
sw
Heetgasvoeler
TWA
bl
2
Codeer weerstand, 2700 Ohm
sw
RD
CW
Indien ingebouwd: Warmtebron uitgangssensor
X52
Retourvoeler
sw
R6
-F2
PE
TVL
R4
TRL
Stekker in schakelkast warmtepomp (sensorkabel)
TVL
THG
R5
K1
PE
F1 Hogedrukpressostaat
K3
TWEFS
ASD
Lagedrukpressostaat
-X52
Ontdooiventiel
E1 Pressostat voor ontdooien
Legenda:
NDP
TRL
ZW1
STB
Y1
Veiligheidstemperatuurbegrenzer elektrischverwarmingselement
-Y1
Beveiliging aanvullende verwarming
Aanvoervoeler
K6
L1 VD1HD
Bedrijfsmiddel
-X12
F2
VBO
Stekker in schakelkast warmtepomp (stuurstroomkabel)
Beveiliging ventilator
VD1
NL817072a
R10
R3
Aansluitstrip in schakelkast warmtepomp
MOT
X7
X12
Beveiliging compressor 1
HDP
Functie
AEP
21.01.2016
PEP 013/2008
2
Achim Pfleger
10X431 - 10X432;
-
2/2
Achim Pfleger 05.03.2009
LW 90-140 A/RX
817072
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
a ÄM 066/2015
Bl von Anz
Naam
Datum
Toestand
Bladnr.
Bewerking
Datum
Wijziging
LW 90A/RX – LW 140A/RX Stroomschema 2/2
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alpha innotec LW 90A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alpha innotec LW 90A in the language / languages: Dutch as an attachment in your email.

The manual is 3,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info