iLive Fixed Format Getting Started Guide 25 AP7141 iss.5
Scene Recall Safes lets you make selected input
channels, mix and DCA masters 'safe' so that their
parameters are not overwritten when a Scene is recalled.
Hold down the SCENE SAFES key and press the strip MIX
keys on channels you want to make safe. The SAFE icon in
the strip LCDs turns on for channels made safe.
Preamp Safes The mic preamp is automatically included
in channels made safe. If you do not want to make the
preamp safe, for example because you have patched it to
more than one input channel, you can change its safe status
using the Preamp screen Safe button.
Show memories
You can archive your configuration as a Show memory.
Show memories overwrite all the settings. These include
all current parameters, system DSP and control
configuration, all 250 Scenes and the user preferences.
Shows are stored on the TouchScreen computer within the
Surface and can be transferred between systems using a
USB key.
To archive your configuration go to the UTILITY /
Configuration / Show Manager screen. Touch the Archive
Show button. Type in a name using the onscreen keypad.
Press Enter to archive the show. This takes a few seconds to
complete.
Use the + button to Expand the list of Shows currently
stored. Template Shows are factory defaults that cannot be
deleted. They give you a quick starting point for mixing with
iLive and can be edited to create your own User shows.
To overwrite an existing User Show highlight it in the list and
touch Archive. The keypad opens with its name displayed.
Either type in a new name to archive it as a different show, or
just press Enter to overwrite the existing show.
To recall a Template, User or USB show go to the UTILITY /
Configuration / Show Manager screen, highlight a Show in
the list, then touch the Recall button. Confirm the action.
Note - Recalling a show overwrites all the system settings
and can change your mix architecture and patching. Make
sure existing settings are archived first if you want to keep
them to use again in the future. Show recall can take up to 3
minutes depending on how much information is stored.
Note - Show recall should only be used when reconfiguring
your system for a different event. This would typically be
done once for the event. Use the Scene memories rather
than Shows to recall settings for different scenes in a theatre
performance, bands at a music festival, day to day setups in
a church, and so on.
Note - For iLive to see the Shows on your USB key they
should be placed in an 'allenheath \ shows' folder in the root
directory of your key. If you have previously archived Shows
to the key using an iLive then this folder should have already
been created.
In situations where you want to import settings from a guest
engineer’s USB key but do not want to overwrite all the
system settings, you can use the USB Scene Transfer
function available in the UTILITY / Configuration screen.
Refer to the TouchScreen HELP manual for further
information.
Scene transfer Filter
User Show list
Factory default Template shows
Archive existing settings
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allen-Heath iLive at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allen-Heath iLive in the language / languages: English as an attachment in your email.

The manual is 2,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info