541382
43
Zoom out
Zoom in
Previous page
1/47
Next page
iDR-8 User Guide 43
Network Port
For system configuration and control using iDR
System Manager and PL Client software
RJ45 TCP/IP Ethernet
MDI/X switch for hub or direct to PC connection
Setup DHCP on/off, IP address, subnet mask
CAT5 UTP cable up to 100 metres (330 feet)
Communications Port Options
Always available – TCP/IP network, DR-Link
Selectable combinations:
RS232 + SysNet
RS232 + MIDI
RS232 + PL-Anet
SysNet + PL-Anet
MIDI + PL-Anet
Sys-Net + MIDI
Available ports indicated by active LEDs
RS232
Uses PPP dial-up connection
Settings Host, Client IP address, username, password
Baud rate 115200, 8N1
Cable length <3 metres (10 feet)
Front Panel RS232 Port
For code update via PC
Use standard 9pin male to female RS232 cable
Connects to PC COM1 or COM2 port
Rear Panel RS232 (MODEM) Port
For connection to modem or PC
Use standard 9pin female to male cable to modem
Use 9pin female to female null modem cable to PC
MIDI
Remote parameter control, show automation
Opto-isolated MIDI in, thru, out on 5pin DIN socket
Note on/off, program change, NRPN
Channel set to 1
Refer to Allen & Heath iDR MIDI protocol
SysNet
Remote parameter control using third party controllers
9pin D female RS232
Baud rate 19200, 8N1
Cable length <3 metres (10 feet)
Refer to Allen & Heath iDR SysNet protocol
PL-Anet Port
Serial port for daisy chained Allen & Heath PL
intelligent remote controllers
Proprietary Allen & Heath control protocol
RJ45 RS485 with +20V DC phantom power
Requires end-of-line termination
CAT5 STP cable, follows EIA/TIA 568B standard
Refer to Allen & Heath application chart for lengths
DR-Link Port
Serial control of iDR expander units
Proprietary Allen & Heath control protocol
RJ45 connector
IN and OUT ports provided on expanders to allow
daisy chaining through multiple units
CAT5 STP cable up to 300 metres (1000 feet)
iDR-switch Inputs x24
Contact closure to connect pin to ground
Opto-isolated via 2k2 ohm from internal +10V supply
Sink current 5mA,
Maximum cable resistance 1k ohm
3x 10way Phoenix connectors, 8 switches per
Mating screw terminal plugs supplied
Ground screws provided for cable shields
iDR-switch Logic Outputs x16
Opto-isolated open collector
Floating collector (+) and emitter (-) terminals
Internal DC source provided +10V 500mA total max
External DC supply maximum +24V
Up to 200mA current sink per output
Ground screws provided for cable shields
Power Supply
Universal mains input switched mode design
IEC 3pin, country dependent mains lead supplied
Rear panel power on/off switch
AC mains input 100-240V AC 50/60Hz
Variable speed cooling fan in iDR-8
iDR-8 80VA max, T1.6AL 20mm fuse
iDR-in, iDR-out 25VA max, T500mAL 20mm fuse
iDR-switch 15VA max, T500mAL 20mm fuse
Mechanical
19” rack or stand alone desk/shelf mount
Removable rack ears, press-in rubber feet
Width x Depth x Height
iDR-8 2U rack 483 x 360 x 88mm
19” x 14.2” x 3.5
Desk 443 x 360 x 92mm
17.4” x 14.2” x 3.6”
Weight 7kg, 15.4 lbs
iDR-in, iDR-out 1U rack 483 x 232 x 44mm
19” x 9.1” x 1.7”
Desk 443 x 232 x 48mm
17.4” x 9.1” x 1.9”
Weight 3.5kg, 7.7 lbs
iDR-switch 1U rack 483 x 144 x 44mm
19” x 5.7” x 1.7”
Desk 443 x 144 x 48mm
17.4” x 5.7” x 1.9”
Weight 2.2kg, 5 lbs
Allow extra 75mm (3”) depth for connectors
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allen-Heath iDR-8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allen-Heath iDR-8 in the language / languages: English as an attachment in your email.

The manual is 6,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info