Using PFL / AFL Allen & Heath are renowned for bringing you
the most comprehensive engineer’s monitoring system in consoles at
this price point. We recognise the importance of correct gain structure
and signal handling. The GL2400 includes LED meters for every
input channel and main output, as well as a pair of high resolution
meters dedicated to monitor duty only. In monitor mode the M fader
and associated controls become a full featured PFL/AFL monitor feed
for the engineer’s listen wedge.
The input channels provide PFL (pre-fade listen) so that each source
can be checked using the meters and headphones before you bring
the fader up. You can even use PFL while the channel is muted to
prevent the signal reaching the house and monitor speakers until you
have checked it and are ready.
All the main, aux and matrix outputs provide AFL (after-fade listen) so
that you can check the exact level leaving the console. Once again,
the AFL switch gets its source before the output mute switch so that
you can check the signal before you send it to its destination. This
can be very important when you are feeding remote destinations such
as broadcast and recording.
The Decibel the ‘Bell’ is the unit of sound level. Decibel is 1/10
Bell, a more conveniently sized unit. dB = 20 log (Vo / Vi) where Vi
and Vo are two signal voltages, in and out (ignoring the impedances).
The dB is used to express the relationship between two levels, chosen
because of the logarithmic way our ears respond to sound. The ‘dB’
relates one level to another. For example, a preamp with a gain of
40dB (100x) would produce an output of +10dBu for an input of -
30dBu. Several audio standards exist to relate a signal level to a
known reference. Audio engineers need to deal with a variety of
equipment standards, for example, a -10dBV CD player plugged into a
console with +4dBu outputs connected to a 0dBu input DSP speaker
manager, or an operator using an SPL (sound pressure level) meter to
measure sound intensity.
dBu Relative to 0.775Vrms – professional standard
0dBu = 0.775V +4dBu = 1.228V
dBV Relative to 1Vrms - consumer audio standard
0dBV = 1V -10dBV = 316mV = -8dBu
dB-A Sound pressure with a filter contour to approximate
the response of the human ear. Three curves A, B,
C exist for different loudness.
dBfs Relative to signal maximum before clip (full scale)
Using Inserts The GL2400 channel inserts operate at 0dBu,
the output inserts operate at -2dBu. In practice this makes little
difference as long as the inserted equipment is intended for line level
operation (-6 to +4dBu). Simply set the gain through the device to
unity (0dB) with the bypass switch pressed (if available). With the
effect switched in, use the console channel gain control to make any
further adjustments needed. This keeps the gain structure correct
through the channel signal path.
With nothing plugged into the insert, the channel signal is routed
through a switching (‘normalling’) contact in the socket. As soon as a
jack is plugged into the socket the contact is opened and the signal
path broken so that the external device can be patched in series with
the signal.
AFL
dB
SEND
INSERT
RETURN
TIP
RING
If you suspect the insert
socket to be faulty or
intermittent through excessive
wear or contamination, test for
this by plugging in a jack with
its tip shorted to its ring
contact. This bypasses the
contact in the socket. Clean
using suitable electrical
contact cleaner.
Tech talk…
For an audio circuit stage:
Pi = Input signal power
Po = Output signal power
The Decibel is defined as:
dB = 10 log (Po / Pi)
= 10 log (Vo
2
/Ro / Vi
2
/Ri)
If input and output impedances
Ri and R0 are the same, then:
dB = 20 log (Vo / Vi)
dBm is defined as 1mW into
600 ohms = 0.775V
dBu = 0.775V ignoring the
600 ohms as we assume high
input and low output
impedance and therefore
maximum voltage transfer
between stages, appropriate
for modern audio.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allen-Heath GL 2400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allen-Heath GL 2400 in the language / languages: English as an attachment in your email.

The manual is 4,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info