Getting started...
Required tools list
1. Screw driver
2. Electric drill, hole core
drill (60 mm)
3. Hexagonal wrench
4. Spanner
5. Pipe cutter
6. Reamer
7. Knife
8. Gas leak detector
9. Measuring tape
10. Thermometer
11. Megameter
12. Multimeter
13. Vacuum pump
14. Gauge manifold
(for R-410A)
15. Torque wrench
18 Nm (1.8 kgf.m)
45 Nm (4.5 kgf.m)
65 Nm (6.5 kgf.m)
75 Nm (7.5 kgf.m)
85 Nm (8.5 kgf.m)
ATTENTION
1. Selection of the units location. Select a location which is
rigid and strong enough to support or hold the unit and
select a location for easy maintenance.
2. Do not release refrigerant during piping work for installation,
reinstallation and during repairing a refrigeration parts.
Take care of the liquid refrigerant, it may cause frostbite.
3. Installation work. It may need two people to carry out the
installation work.
4. Do not install this appliance in a laundry room or other
location where water may drip from the ceiling, etc.
SAFETY PRECAUTIONS
Read the following "SAFETY PRECAUTIONS" carefully be fore
installation.
Electrical work must be installed by a licensed electrician. Be
sure to use the correct rating of the power plug and main circuit
for the model to be installed.
The caution items stated here must be followed because
these important contents are related to safety. The meaning of
each indication used is as below. Incorrect installation due to
ignoring of the instruction will cause harm or damage, and the
seriousness is classified by the following indications.
Carry out test running to confirm that no abnormality occurs
after the installation. Then, explain to user the operation, care
and maintenance as stated in instructions. Please remind
the customer to keep the operating instructions for future
reference.
The items to be followed are classified by the symbols:
WARNING
This indication shows
the possibility of causing
death or serious injury.
Symbol with background
white denotes item that in
PROHIBITED from doing.
WARNING
CONTENTS
1. Use qualified installer and follow careful this instructions, otherwise it
will cause electrical shock, water leakage, or aesthetic problem.
2. Install at a strong and firm location which is able to withstand the
set’s weight. If the strength is not enough or installation is not
properly done, the set will drop and cause injury.
3. For electrical work, follow the local national wiring standard, regulation
and this installation instruction. An independent circuit and single
outlet must be used. If electrical circuit capacity is not enough it
will cause electrical shock or fire.
4. Use the specified cable and connecting tightly for indoor/outdoor
connection. Connect tightly and clamp the cable so that no
external force will be acted on the terminal. If connection or fixing
is not perfect, it will cause heat-up or fire at the connection.
5. Wire routing must be properly arranged so that control board cover
is fixed properly. If control board cover is not fixed perfectly, it will
cause heat-up at connection point of terminal, fire or electrical
shock.
6. Before obtaining access to terminals, all supply circuits must be
disconnected
7. When carrying out piping connection, take care not to let air substance
other than the specified refrigerant go into refrigeration
cycle, otherwise, it will cause lower capacity, abnormal
high pressure in the refrigeration cycle, explosion or injury.
8. Do not damage or use unspecified power supply cord.
Otherwise, it will cause fire or electrical shock.
9. Do not modify the length of the power supply cord or use of
the extension cord, and do not share the single outlet with
other electrical appliances. Otherwise, it will cause fire or
electrical shock.
10. This equipment must be earthed. It may cause electrical shock if
grounding is not perfect.
11. Do not install the unit at place where leakage of flammable gas may
occur. In case of leaks and accumulates at sur rounding of the unit,
it may cause fire.
12. Carry out drainage piping as mentioned in installation instructions.
If drainage is not perfect, water may enter the room and damage
the furniture.
13. If supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a
hazard.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for they safety. Children should be supervised to ensure that their do not play with the appliance
3
Installation/Service Tooling ..................................................... 4
Attached Accessories
............................................................ 4
General precautions ............................................................. 5
Outdoor unit .......................................................................... 6
Unit dimensions
Disposal of outdoor unit
Several outdoor installation
Pipes connections
................................................................ 8
Cutting and flaring
Pipe insulation
Pipe connections to unit
Evacuation of pipes and indoot unit
Electrical connection
......................................................... 10
Feature setup .......................................................................11
Installation test ................................................................... 14
16
Please refer to indoor unit installation manual supplied with the indoor unit!
Check list before operation
...............................................
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Airwell Multisplit YAZE CINCO DCI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Airwell Multisplit YAZE CINCO DCI in the language / languages: English as an attachment in your email.

The manual is 1,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info