525525
2
Zoom out
Zoom in
Previous page
1/28
Next page
EN 2
661Y0200.E
ENGLISHFRANCAISNEDERLANDSESpAñoLITALIANo
РУССКИЙ
DEuTSCH
DESCRIPTION OF FUNCTION
“Tank-in-Tank” system
“Tank-in-Tank” is a heat exchanger with a built-in accumulator, made
up of two concentric tanks: the inner tank contains domestic water
to be reheated (secondary) and the outer tank contains the heating
fluid (primary) which circulates between the two tanks and transfers
its heat to the domestic water.
Domestic Hot Water cylinder
The inner tank is the heart of the tank: it is subject to the
aggressiveness of the supply water, to high pressures and to
variations in temperature. This tank is made of solid chrome-
nickel stainless steel (stainless steel 304), fully welded under argon
protection using the Tungsten Inert Gas (T.I.G.) technique.
Before assembly, the convex bottoms are pickled and passivated in
order to improve the tanks lifespan and in particular its resistance to
corrosion. The shell is corrugated all the way up using an exclusive
manufacturing process. This design gives considerable resistance to
pressure and limits the adherence of lime scale by allowing the tank
to expand and contract.
Outer tank
The outer tank containing water from the primary circuit arriving
from the boiler, is made of carbon steel STW 22.
Thermal Insulation
This is carried out using high density injected polyurethane
foam, 50 mm containing no CFCs.
Lining
The tank is covered using polypropylene, a plastic material
which offers a high resistance to shocks and which is also very
pleasing to the eye.
Optional heating element for SLE Plus
The SLE tanks can be installed with a self- controlled heating
element with built-in control and safety thermostats.
The control thermostat of the tank can not control the heating
element.
DESCRIPTION OF OPERATION
Operating cycle
The thermostat is triggered and starts up the pump which circu-
lates the heating water. This water circulates around the inside tank
and heats up the domestic water. When the required temperature
is reached, the thermostat stops the primary circulating pump.
OFF Reheating Running Storing
Cold Water
Heating fluid
Domestic hot water
Volt Amp Power Code
1 x 230 V 13 3 kW 10800081
3 x 400 V + N 4.4 3 kW 10800082
1 x 230 V 26 6 kW 10800083
3 x 400 V + N 8.8 6 kW 10800084
INTRoDuCTIoN
Losses when shut down in Watt
Models
Losses when shut down
[Watt]
SLE Plus 210 ∆T = 50°C 85,6
SLE Plus 240 ∆T = 50°C 88,8
SLE Plus 300 ∆T = 50°C 93,2
Temperature losses with ambient T° of 20°C
1. Auxiliary connection DHW
2. Cold water inlet connection + PVCC plunger
3. Flow primary circuit (tank loading)
4. Auxiliary heating return
5. Polyurethane foam insulation
6. Auxiliary heating return
7. Flow primary of heat pump
8. Return primary of heat pump
9. Electric heating element (in option)
10. Manual air purge
11. Hot water connection
12. Polypropylene top lid
13. Stainless steel dry well
14. Stainless steel tank (DHW)
15. Flow heating circuit
16. Return heating circuit
17. Outer steel tank (primary circuit)
18. Polypropylene shell
19. Polypropylene bottom lid
1 10
2
3
8
7
6
4
5
9
11
12
17
16
15
13
14
19
18
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV SLE PLUS 210 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV SLE PLUS 210 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 2,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info