User manual Upsilon boiler
These operation instructions describe the functioning and the operating of the
Upsilon boilers. This manual is for the end user. For installation and servicing
there is an installation & servicing instructions manual for the installer.
Read this manual fully before operating the boiler. In case of doubt or errors
contact your installer.
A.O. Smith reserves the right to change the specications and dimensions
without prior notice.
Safety
The device may be operated only by authorized persons who have
been instructed on the operation and use of the device. Improper use
may cause damage to the device and / or to the connected installation.
The appliance is not to be used by children or persons with reduced
physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instructions.
Children being supervised are not to play with the appliance.
Work on the boiler must be carried out by a competent person, (Ref:
Gas Safe Register) using correctly calibrated instruments with current
test certication. When replacing parts use only A.O. Smith Service
parts. Contact details for A.O. Smith can be found on the back page
of this manual.
In case you smell gas:
- No naked ames! Do not smoke!
- Do not operate electrical switches for lights or any other appliance
- Do not use a telephone
- Turn off gas supply at meter
- Open windows and doors
- Notify any persons in the building and leave the building at once
- Call Gas company or installer only when outside the building
Protection for corrosion
Do not use any sprays, chlorine containing agents, solvents, paint etc. around
the boiler or around the air intake supply entrance of the boiler. These substan-
ces have negative inuences on the boiler and can lead to corrosion resulting
in failure of the boiler.
Checking the water pressure
Check the water pressure in the central heating installation regularly.
Use only potable water for lling.
Additives only after clearance by A.O. Smith.
Contact your installer in case of doubt.
Description of the boiler
The Upsilon boiler is a room sealed, condensing and modulating central heating
boiler and meets the European requirements (CE). A declaration of conformity
is available on demand from the supplier.
The efciency of the boiler is very high and the radiation convection and standby
losses very low. The emission of noxious substances is far below the xed
standards so the boiler meets the requirements of today.
If changes are made to the boiler construction the boiler no longer complies
with the CE requirements.
Information and operation of the boiler
Screen User manual
T3
DHW
230V~
AC
230V
out
230V~
AC
230V
out
L
N
L
N
L
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8
NN
L
N
L
P3
Error
Heat
demand
LPG
On/Off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
T10
End
switch
Blocking
Switch
Open-
Therm
LWCO
0-10Volt
230V Pump / 3-WV.230V Damper230V DHW pump230V out230V~ AC
T4
Out
On/Off
L
MBoiC
Keyboard Main switch
Screen
The LCD screen is backlit. The light is activated by pushing one of the buttons
There are 2 light colours available. The various colours indicate the following:
Blue Basic level
Red Problem display
Having pressed the last button, the screen light stays on for 2 minutes.
Screen explanation
9 10 11 12 13
1 5
2 6
3 7
4 8
1. CH-program active
2. DHW-program active
3. Clock program active (CH and/or DHW)
4. Pump continuously active or pumps active when frost protection
is active
5. Boiler off at:
outside temperature > T-day (when day temperature is active)
or > T-night (when night temperature is active)
6. System pump on
7. Burner on.
Starts ashing during ignition, continuous when burner is on.
8. Chimney sweep function (100% power for emission measurement)
. .. 9. Boiler address:
1 = Cascade Master
2..8 = Cascade Slaves
10. Identication burner inside boiler
11. Night temperature active
12. Day temperature active
13. 2 text lines with 8 characters each
The operational status, messages and possible errors are displayed
here.
Operational status
- Standby Standby. Boiler is ready for operation.
- Vent.Phase Ventilation stage
- Ignition phase Ignition stage
- Burner lit CH Burner active for heating
- Burner lit DHW Burner active for hot water
- CH T > Tset Burner off on account of too high ow temperature CH
- Overrun CH Overrun time pump over CH
- Overrun DHW Overrun time pump over DHW
- Service Boiler needs maintenance. Contact installer
- Frost Burner active for frost protection
Explanation keyboard
Value increase / change
Emission Back / correction
measurement
Backward Forward
Reset* Conrm selection
Value decrease / change
* Reset
Reset only functions in case of an Error or certain Messages. If reset is
rapidly pressed over a short period of time, the device will block comple-
tely. Only loss of power (main switch) will restart the device completely.
Recommendation: contact your installer and inform them about the fault and
give them the number code.
The main switch is located on the right hand side of the keyboard. This switch
controls the 230V power supply.
Standard read-out
Standard read-out: Good
we 10:17
Good indicates that the boiler operates normally (burner on
or off)
we 10:17 indicates the actual day and time.
The standard read-out offers 3 information screens.
Switching to different screen can be found using the + or -
button.
1. “Good”-read-out Good with actual day and time
(see above)
2. Operational status Refer to the explanation of texts
at the top of this page
3. Technical read-out Actual water ow
temperature. (T1 in °C)
and water pressure
(P in bar).
See other side
R
OK
-
+
R
OK
-
+
Standby
Good
we 10:17
20.0 °C
1.65 bar
OK
-
+
OK
-
+
User manual
8G.52.91.03 / 04.13 Changes reserved. E.&O. E.
0310 384
A B C D
E F G H
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Upsilon UB-70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Upsilon UB-70 in the language / languages: English as an attachment in your email.

The manual is 1,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Upsilon UB-70

A.O. Smith Upsilon UB-70 Installation Guide - English - 68 pages

A.O. Smith Upsilon UB-70 Additional guide - English, Dutch - 2 pages

A.O. Smith Upsilon UB-70 User Manual - Dutch - 2 pages

A.O. Smith Upsilon UB-70 Installation Guide - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info