1.4 Technical safety equipment
1.4.1 Gas control valve
The water heater is equipped with a gas
control wich regulates the ow of gas to
the burner. The gas block is equipped
with a safety valve, gas valve and burner
control (on a standard natural gas
setting). To ensure improved ignition the
gas control valve opening mechanism
is tted with a delay (softlite). The gas
control block is suitable for gasses from
the rst, second and third gas family. The
maximum inlet pressure is 60 mbar.
The automatic incandescent ignition (hot
surface) ensures that the burner ignites
as soon as there is a demand for heat.
1.4.2 Control panel
Temperature control for the water heater
is housed in the control panel (See gur
2). For safety purposes, heaters are
always tted with two thermostats: a
control thermostat is adjustable between
40 °C and 80 °C and a safety thermostat
90 °C. The control panel is tted with
an ON/OFF switch (I/0). At setting
”I”, the gas control is activated on the
basis of heat demand from the control
thermostat. At setting ”0” the heater is
switched off.
6
1.2 Technical safety
equipment
1.2.1 Gas control valve
The water heater is equipped with a gas
control wich regulates the ow of gas to
the burner. The gas block is equipped
with a safety valve, gas valve and burner
control (on a standard natural gas
setting). To ensure improved ignition the
gas control valve opening mechanism is
tted with a delay (softlite).
The gas control block is suitable for
gasses from the rst, second and third
gas family. The maximum inlet pressure
is 60 mbar.
The automatic incandescent ignition (hot
surface) ensures that the burner ignites
as soon as there is a demand for heat.
1.2.2 Control panel
Temperature control for the water heater
is housed in the control panel (See gur
2). For safety purposes, heaters are
always tted with two thermostats: a
control thermostat is adjustable between
40 °C and 80 °C and a safety thermostat
90 °C. The control panel is tted with
an ON/OFF switch (I/0). At setting
”I”, the gas control is activated on the
basis of heat demand from the control
thermostat. At setting ”0” the heater is
switched off.
A) Hot water outlet
B) Cold water inlet
1) Electrical connection
2) ON/OFF switch
3) Ignition controller reset button
4) Control thermostat knob
5) Safety thermostat reset button
Figur 2 - Top view of the heater
1129
A) Hot water outlet
B) Cold water inlet
1) Electrical connection
2) ON/OFF switch
3) Ignition controller reset button
4) Control thermostat knob
5) Safety thermostat reset button
Figure 2 - Top view of the heater
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith BTI 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith BTI 100 in the language / languages: English as an attachment in your email.

The manual is 0,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info